Cat. No. | Description | No. of Slots | Dimensions (HxWxD), Approx. | Weight | Mounting |
1746-A4 | I/O chassis for 1746 I/O modules | 4 | 171 x 177 x 145 mm (6.73 x 6.97 x 5.71 in.) | 0.7 kg (1.6 lb) | Back-panel mount |
1746-A7 | I/O chassis for 1746 I/O modules | 7 | 171 x 282 x 145 mm (6.73 x 11.11 x 5.71 in.) | 1.1 kg (2.4 lb) | Back-panel mount |
1746-A10 | I/O chassis for 1746 I/O modules | 10 | 171 x 397 x 145 mm (6.73 x 15.64 x 5.71 in.) | 1.5 kg (3.3 lb) | Back-panel mount |
1746-A13 | I/O chassis for 1746 I/O modules | 13 | 171 x 502 x 145 mm (6.73 x 19.78 x 5.71 in.) | 1.9 kg (4.2 lb) | Back-panel mount |
Cat. No. | Description | Length |
1746-C7 | Connects 1746 chassis to extend the backplane from one to the other | 0.15 m (0.5 ft) |
1746-C9 | Connects 1746 chassis to extend the backplane from one to the other | 0.91 m (3.0 ft) |
1746-C16 | Connects 1746 chassis to extend the backplane from one to the other | 1.22 m (4.0 ft) |
Cat. No. | Description |
1746-N2 | Slot Filler—Covers any unused I/O slot in a chassis. The slot filler helps guard against debris falling into the slot, possibly causing a short on the backplane. |
1746 Digital AC Input Modules
Cat. No. | Operating Voltage | Signal Delay, Max. | Off-State Current, Max. | Number of Inputs | Backplane Current Load @ 5V | Applications |
1746-IA4 | 85…132V AC | on = 35 ms off = 45 ms | 2 mA | 4 | 35 mA | General-purpose 120V AC inputs |
1746-IA8 | 2 mA | 8 | 50 mA | |||
1746-IA16 | 2 mA | 16 | 85 mA | |||
1746-IM4 | 170…265V AC | on = 35 ms off = 45 ms | 2 mA | 4 | 35 mA | General-purpose 220/240V AC inputs |
1746-IM8 | 2 mA | 8 | 50 mA | |||
1746-IM16 | 2 mA | 16 | 85 mA | |||
1746-IN16 | 24V AC DC Sink (Source Load) | on = 15 ms DC off = 15 ms DC on = 25 ms AC off = 25 ms AC | 1 mA | 16 | 85 mA | V-AC or V-DC operation |
1746 Digital DC Input Modules
Cat. No. | Operating Voltage | Signal Delay, Max. | Off-State Current, Max. | Number of Inputs | Backplane Current Load @ 5V | Applications |
1746-IG16 | 4.5…5.5V DC source (sink load) | on = 0.25 ms off = 0.50 ms | — | 16 | 140 mA | • TTL input • BCD inputs |
1746-IB8 | 10…30V DC sink (source load) | on = 8 ms off = 8 ms | 1 mA | 8 | 50 mA | General-purpose DC inputs |
1746-IB16 | 10…30V DC sink (source load) | 1 mA | 16 | 85 mA | ||
1746-IV8 | 10…30V DC source (sink load) | on = 8 ms off = 8 ms | 1 mA | 8 | 50 mA | |
1746-IV16 | 1 mA | 16 | 85 mA | |||
1746-ITV16 | on = 0.3 ms⋆ off = 0.5 ms | 1.5 mA | 16 | 85 mA | Fast response for time-critical applications | |
1746-ITB16 | 10…30V DC sink (source load) | on = 0.30 ms⋆ off = 0.50 ms | 1.5 mA | 16 | 85 mA | |
1746-IB32 | 15…30V DC sink (source load) | on = 3 ms off = 3 ms | 1 mA | 32 | 106 mA | General-purpose DC inputs. High-density for limited panel space |
1746-IV32 | 15…30V DC source (sink load) | on = 3 ms off = 3 ms | 1 mA | 32 | 106 mA | |
1746-IC16 | 30…55V DC sink (source load) | on = 4 ms off = 4 ms | 1.5 mA | 16 | 85 mA | General-purpose 48V DC inputs |
1746-IH16 | 90…146V DC‡ sink (source load) | on = 9 ms off = 9 ms | 0.8 mA | 16 | 85 mA | General-purpose 125V DC inputs |
⋆ Typical signal delay for these modules: on = 0.1 ms, off = 0.25 ms @ 24V DC. ‡ Consult the user manual for module deratings at 146V DC and 60 °C. |
1746 Digital AC Output Modules
Cat. No. | Operating Voltage | Continuous Current per Output, Max. | Continuous Current/Module, Max. | Number of Outputs | Backplane Current Load | Applications |
1746-OA8 | 85…265V AC | 1.0 A at 30 °C 0.5 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 8 | 185 mA at 5V | General-purpose 120/240V AC outputs |
1746-OA16 | 0.5 A at 30 °C 0.25 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 16 | 370 mA at 5V | ||
1746-OAP12 | 2.0 A at 30 °C 1.25 A at 55 °C 1.0 A at 60 °C | 9.0 A at 30 °C 6.0 A at 60 °C | 12 | 370 mA at 5V | High-current 120/240V AC outputs; 6 outputs per common; fused commons protect module | |
1746 Digital DC Output Modules
Cat. No. | Operating Voltage | Continuous Current per Output, Max. | Continuous Current/Module, Max. | Number of Outputs | Backplane Current Load | Applications |
1746-OB6EI | 10 …30V DC source | 2.0 A at 0…60 °C | 12 A at 0…60 °C | 6 | 46 mA at 5V | Individually isolated electronically fused DC outputs that automatically reset |
1746-OB8 | 10…50V DC source | 1.0 A at 30 °C 0.5 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 8 | 135 mA at 5V | General-purpose DC outputs |
1746-OV8 | 10…50V DC sink | 1.0 A at 30 °C 0.5 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 8 | 135 mA at 5V | General-purpose DC outputs |
1746-OB16 | 10…50V DC source | 0.50 A at 30 °C 0.25 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 16 | 280 mA at 5V | General-purpose DC outputs |
1746-OB16E | 10…30V DC source | 1.00 A at 30 °C 0.50 A at 60 °C | 8 A at 0…60 °C | 16 | 135 mA at 5V | Electronically fused DC outputs that automatically reset |
1746-OV16 | 10…50V DC sink | 0.5 A at 30 °C 0.25 A at 60 °C | 8 A at 30 °C 4 A at 60 °C | 16 | 270 mA at 5V | General-purpose DC outputs |
1746-OBP8 | 20.4…26.4V DC source | 2.0 A at 60 °C | 8.0 A at 0…60 °C | 8 | 135 mA at 5V | High-current DC source output |
1746-OBP16 | 20.4…26.4V DC source | 1.5 A at 30 °C 1.0 A at 60 °C | 6.4 A at 0…60 °C | 16 | 250 mA at 5V | High-current DC source output |
1746-OVP16 | 20.4…26.4V DC sink | 1.5 A at 30 °C 1.0 A at 60 °C | 6.4 A at 0…60 °C | 16 | 250 mA at 5V | High-current DC sink output, fused common |
1746-OG16 | 5V DC sink | 0.024 A | 0.384 A | 16 | 180 mA at 5V | TTL loads; sink-load display devices |
1746-OB32 | 5…50V DC source | 0.5 A at 30 °C 0.2 A at 60 °C | 8.0 A at 0…60 °C | 32 | 190 mA at 5V | High-density low-current DC outputs |
1746-OB32E | 10…32V DC source | 0.5 A at 30 °C 0.25 A at 60 °C | 8.0 A at 0…60 °C | 32 | 190 mA at 5V | Electronically fused DC outputs that automatically reset |
1746-OV32 | 5…50V DC sink | 0.5 A at 30 °C 0.25 A at 60 °C | 8.0 A at 0…60 °C | 32 | 190 mA at 5V | High-density low-current DC outputs |
1746 Digital Contact Output Modules
Cat. No. | Operating Voltage | Continuous Current per Output, Max.⋆ | Continuous Current/Module, Max. | Number of Outputs | Type of Contact Outputs | Backplane Current Load | Applications |
1746-OX8 | 5…125V DC 5…265V AC | 3 A at 120V AC 1.2 A at 24V DC | See‡ | 8 | N.O. relay contact outputs | 85 mA at 5V DC 90 mA at 24V DC | Individually isolated high-current relay contact outputs |
1746-OW4 | 1.5 A at 120V AC 1.2 A at 24V DC | 8 A | 4 | 45 mA at 5V DC 45 mA at 24V DC | Relay contact outputs | ||
1746-OW8 | 1.5 A at 120V AC 1.2 A at 24V DC | 16 A 8 A per common | 8 (2 sets of 4) | 85 mA at 5V DC 90 mA at 24V DC | Relay contact outputs; 4 outputs per common | ||
1746-OW16 | 1.5 A at 120V AC 1.2 A at 24V DC | 16 A‡ 8 A per common | 16 (2 sets of 8) | 170 mA at 5V DC 180 mA at 24V DC | Relay contact outputs; 8 outputs per common | ||
⋆ Inductive load rating. ‡ The continuous current per module must be limited to 1440 VA. |
1746 Digital I/O Combination Modules
Cat. No. | Inputs | Outputs | Backplane Current Load | Applications | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Operating Voltage | Signal Delay, Max. | Off-State Current, Max. | Number of Inputs | Operating Voltage/ Type | Continuous Current per Output, Max .⋆ | Number of Outputs | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1746-IO4 | 85…132V AC | on = 35 ms off = 45 ms | 2 mA | 2 | 5…265V AC 5…125V DC N.O. relay contact | 1.5 A at 120V AC 1.2 A at 24V DC | 2 | 30 mA at 5V DC 25 mA at 24V DC | Combination 120V AC inputs and relay contact outputs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1746-IO8 | 4 | 4 | 60 mA at 5V DC 45 mA at 24V DC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1746-IO12 | 6 | 6 | 90 mA at 5V DC 70 mA at 24V DC | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
1746-IO12DC | 10…30V DC | on = 8 ms off = 8 ms | 1 mA | 6 | 6 | 80 mA at 5V DC 60 mA at 24V DC | Combination 24V DC inputs and relay contact outputs | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
⋆ Inductive load rating. Analog I/O Modules
1746 Analog Output Modules
1746 Analog Combination Modules
1746 RTD and Thermocouple Modules 1746 Removable Terminal Blocks